COPYRIGHTⓒ (주)녹색기술단.
ALL RIGHTS RESERVED. DESIGNED BY BIZVALLEY.
Characteristics of the Condensed Water
- CODcr 10,000~15,000 PPM, NH3-N 500~1,500 PPM
- Contains a high concentration of organic solvents, VOCs, and ammonia
Chemical treatment (Pre-treatment)
- Removal of SS, oil, heavy metals (simple coagulation precipitation)
- Control pH for the evaporator efficiency
Evaporative concentration
- Removal of most of pollutants except VOC, low boiling point substance
- The general operating pH zone is alkali, then the condensed water contains high concentrations of ammonia.
STRIP SYSTEM
- COD removal rate is 40~60%
- T-N removal rate is 90%
Biological treatment
- Removal of residual COD and T-N through nitrification and denitrification
- For reducing the space, we recommend MBR or TUBULAR System
Chemical treatment (Post-treatment)
- Removal of residual COD and T-N by AOP treatment
[Patent] Method of removing nitrogen from hardly decomposable nitrogenous waste water
Capacity | 200㎥/Day |
---|---|
Inflow T-N | 1,000mg/L |
Outflow T-N | 30mg/L |
Con’c of Ammonia solution | 15% |
Capacity | 240㎥/Day |
---|---|
Inflow T-N | 1,000mg/L |
Outflow T-N | 30mg/L |
Con’c of Ammonia solution | 15% |